使用Bonnie进行系统IO性能测试

2010-04-20  范任重 

Bonnie是一款极小的测试系统IO性能的工具,源代码公开.作者主页:
http://www.textuality.com/bonnie/
你也可以点击这里下载

编译Bonnie极其简单,但是需要你安装了makegcc (cc)

 

# makeOptions are "make bsd" and "make SysV" - the default is "bsd".If you get messages about missing functions, try "make SysV."make Bonnie make[1]: Entering directory `/export/home/gqgai/bonnie'cc -O     Bonnie.c   -o Bonniemake[1]: Leaving directory `/export/home/gqgai/bonnie'                      

其使用手册在:

http://www.textuality.com/bonnie/advice.html

测试IO速度:

1.T3阵列速度测试(raid5)

 

# df -kFilesystem            kbytes    used   avail capacity  Mounted on/dev/dsk/c0t0d0s0    1018382  117711  839569    13%    //dev/dsk/c0t0d0s6    2055705 1177602  816432    60%    /usr/proc                      0       0       0     0%    /procfd                         0       0       0     0%    /dev/fdmnttab                     0       0       0     0%    /etc/mnttab/dev/dsk/c0t0d0s1    1448911  772148  618807    56%    /varswap                 4770120       8 4770112     1%    /var/runswap                 4958928  188816 4770112     4%    /tmp/dev/dsk/c5t1d0s0    51634648 35154404 15963898    69%    /data1/dev/dsk/c5t1d1s1    25816144 21498881 4059102    85%    /data3/dev/dsk/c5t1d1s0    25816144 14650723 10907260    58%    /data2/dev/dsk/c0t2d0s1    15483618 1074317 14254465     8%    /temp/dev/dsk/c0t2d0s0    7136886 2824586 4240932    40%    /varlink/dev/dsk/c0t2d0s5    8258597 5868224 2307788    72%    /opt/dev/dsk/c0t2d0s7    2053605 1281342  710655    65%    /export/home/dev/dsk/c0t2d0s6    2053605  178151 1813846     9%    /usr/local# formatSearching for disks...done  AVAILABLE DISK SELECTIONS:       0. c0t0d0           /pci@1f,4000/scsi@3/sd@0,0       1. c0t1d0           /pci@1f,4000/scsi@3/sd@1,0       2. c0t2d0           /pci@1f,4000/scsi@3/sd@2,0       3. c3t0d0           /pci@4,4000/scsi@4/sd@0,0       4. c3t1d0           /pci@4,4000/scsi@4/sd@1,0       5. c3t2d0           /pci@4,4000/scsi@4/sd@2,0       6. c3t3d0           /pci@4,4000/scsi@4/sd@3,0       7. c5t1d0           /pci@1f,2000/SUNW,qlc@1/fp@0,0/ssd@w50020f23000083a2,0       8. c5t1d1           /pci@1f,2000/SUNW,qlc@1/fp@0,0/ssd@w50020f23000083a2,1Specify disk (enter its number): ^D# ./Bonnie -d /data1 -s 2046 -m billing-center File '/data1/Bonnie.8273', size: 2145386496Writing with putc()...doneRewriting...doneWriting intelligently...doneReading with getc()...doneReading intelligently...adoneSeeker 2...Seeker 1...Seeker 3...start 'em...done...done...done...              -------Sequential Output-------- ---Sequential Input-- --Random--              -Per Char- --Block--- -Rewrite-- -Per Char- --Block--- --Seeks---Machine    MB K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU  /sec %CPUbilling- 2046 10251 87.5 32430 55.7 14048 39.5 12625 99.5 48763 67.3  61.5  8.3       

简要介绍一下输出:

这里Sequential Output指写入速度,Char指按字符方式写入,Block指按块方式写入,Rewrite指顺序改写速度(也就是数据修改)
Sequential Input
指读取速度

CPU,指该操作占用的CPU资源.

此处T3 Raid5的写入达到 10251 K/sec

2.本地磁盘速度

# ./Bonnie -d /opt/oracle -s 1024 -m billing-centerFile '/opt/oracle/Bonnie.8545', size: 1073741824Writing with putc()...doneRewriting...doneWriting intelligently...doneReading with getc()...doneReading intelligently...doneSeeker Seeker 2...1...Seeker 3...start 'em...done...done...done...              -------Sequential Output-------- ---Sequential Input-- --Random--              -Per Char- --Block--- -Rewrite-- -Per Char- --Block--- --Seeks---Machine    MB K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU  /sec %CPUbilling- 1024  9582 85.0 15928 29.8  6900 20.3 11735 96.5 46098 67.2 256.6  8.8 

后面会逐渐添加一些其他硬件的测试数据.

3. EMC CLARiiON CX500 测试数据

系统环境:

 # /usr/platform/sun4u/sbin/prtdiag -vSystem Configuration:  Sun Microsystems  sun4u Sun Fire 480RSystem clock frequency: 150 MHzMemory size: 4096 Megabytes ========================= CPUs ===============================================           Run   E$    CPU     CPU  Brd  CPU  MHz   MB   Impl.    Mask ---  ---  ---  ----  -------  ----  A    0   1050  8.0   US-III+  11.0 A    2   1050  8.0   US-III+  11.0 ========================= Memory Configuration ===============================           Logical  Logical  Logical     MC   Bank     Bank     Bank         DIMM    Interleave  InterleavedBrd  ID   num      size     Status       Size    Factor      with---  ---  ----     ------   -----------  ------  ----------  ----------- A    0     0       512MB   no_status     256MB     8-way        0 A    0     1       512MB   no_status     256MB     8-way        0 A    0     2       512MB   no_status     256MB     8-way        0 A    0     3       512MB   no_status     256MB     8-way        0 A    2     0       512MB   no_status     256MB     8-way        0 A    2     1       512MB   no_status     256MB     8-way        0 A    2     2       512MB   no_status     256MB     8-way        0 A    2     3       512MB   no_status     256MB     8-way        0 ========================= IO Cards =========================                     Bus  Max IO  Port Bus       Freq Bus  Dev,Type  ID  Side Slot MHz  Freq Func State Name                              Model---- ---- ---- ---- ---- ---- ---- ----- --------------------------------  ----------------------PCI   8    B    2    33   33  2,0  ok    SUNW,XVR-100                      SUNW,375-3126         PCI   8    B    4    33   33  4,0  ok    fibre-channel-pci10df,f900.10df.+                       PCI   8    B    5    33   33  5,0  ok    fibre-channel-pci10df,f900.10df.+                       PCI   8    A    0    66   66  1,0  ok    pci-pci8086,b154.0/pci108e,1000   PCI-BRIDGE            PCI   8    A    0    66   66  0,0  ok    pci108e,1000-pci108e,1000.1       device on pci-bridge  PCI   8    A    0    66   66  0,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe/pci-bridg+PCI   8    A    0    66   66  1,0  ok    pci108e,1000-pci108e,1000.1       device on pci-bridge  PCI   8    A    0    66   66  1,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe/pci-bridg+PCI   8    A    0    66   66  2,0  ok    pci108e,1000-pci108e,1000.1       device on pci-bridge  PCI   8    A    0    66   66  2,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe/pci-bridg+PCI   8    A    0    66   66  3,0  ok    pci108e,1000-pci108e,1000.1       device on pci-bridge  PCI   8    A    0    66   66  3,1  ok    SUNW,qfe-pci108e,1001             SUNW,pci-qfe/pci-bridg+ =========================  Environmental Status ========================= System Temperatures (Celsius):-------------------------------Device          Temperature     Status---------------------------------------CPU0             50             OKCPU2             52             OKDBP0             28             OK ================================= Front Status Panel:-------------------Keyswitch position: NORMAL System LED Status:   LOCATOR   FAULT    POWER  -------  -------  -------   [OFF]    [OFF]    [ ON] ================================= Disk Status:------------DISK 0: [NO_FAULT]DISK 1: [NO_FAULT] ================================= Fan Status:----------- Bank             RPM    Status----            -----   ------CPU0             5660   [NO_FAULT]CPU1             3896   [NO_FAULT]CPU2             3797   [NO_FAULT]IO0              3947   [NO_FAULT]IO1              4166   [NO_FAULT] =================================   Power Supplies:---------------Supply   Status------   ------PS0      [NO_FAULT]PS1      [NO_FAULT] =================================  ========================= HW Revisions ======================================= System PROM revisions:----------------------OBP 4.10.8 2003/07/25 08:44 IO ASIC revisions:------------------         PortModel     ID  Status Version-------- ---- ------ -------Schizo    8     ok      7   Schizo    9     ok      7  

阵列为CLARiiON CX500,以下分别是4块盘的Raid1+0Raid5的测试数据:

Raid1+0测试

  # ./Bonnie -d /eygle -s 2046 -m jumpFile '/eygle/Bonnie.460', size: 2145386496Writing with putc()...doneRewriting...doneWriting intelligently...doneReading with getc()...doneReading intelligently...doneSeeker Seeker 2...1...Seeker 3...start 'em...done...done...done...              -------Sequential Output-------- ---Sequential Input-- --Random--              -Per Char- --Block--- -Rewrite-- -Per Char- --Block--- --Seeks---Machine    MB K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU  /sec %CPUjump     2046 37438 88.8 111172 63.8 75940 90.0 43495 99.7 322153 99.9 17747.8 177.5                

这里EMC CX500的速度达到了,37438K/sec,T3的性能强了很多

下面是Raid5的测试数据:

 # ./Bonnie -d /eygle -s 2046 -m jumpFile '/eygle/Bonnie.473', size: 2145386496Writing with putc()...doneRewriting...doneWriting intelligently...doneReading with getc()...doneReading intelligently...doneSeeker Seeker 2...1...Seeker 3...start 'em...done...done...done...              -------Sequential Output-------- ---Sequential Input-- --Random--              -Per Char- --Block--- -Rewrite-- -Per Char- --Block--- --Seeks---Machine    MB K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU K/sec %CPU  /sec %CPUjump     2046 40652 95.5 106768 56.1 75673 90.9 43356 99.4 314381 99.8 17347.3 160.5  

 

Raid5这里的字符写速度达到了40652K/sec,Raid1+0稍快,Block方式写Raid1+0Raid5稍快.

实际上EMC一直强调其Raid5读写性能较Raid1+0相差无几.